KG316T Digital Time Switch
KG316T Digital Time Switch
Model:KG316T
Control Voltage :AC 220V (50/60Hz)
Timing Accuracy: ±1 minute/month
Programming Capacity :16 sets of on/off programs (expandable)
Time Range :1 minute to 168 hours (1 week)
Contact Capacity: 25A (resistive load)
Power Consumption: ≤1W
Working Temperature: -10℃ ~ +55℃
Humidity Range: ≤95% RH (non-condensing)
Mounting Type: DIN Rail / Panel Mount
Housing Material: Flame-retardant ABS
Protection Class: IP20
Model:KG316T
Control Voltage :AC 220V (50/60Hz)
Timing Accuracy: ±1 minute/month
Programming Capacity :16 sets of on/off programs (expandable)
Time Range :1 minute to 168 hours (1 week)
Contact Capacity: 25A (resistive load)
Power Consumption: ≤1W
Working Temperature: -10℃ ~ +55℃
Humidity Range: ≤95% RH (non-condensing)
Mounting Type: DIN Rail / Panel Mount
Housing Material: Flame-retardant ABS
Protection Class: IP20
Key Features
✅ Intelligent Microcomputer Control
Built-in high-precision clock chip with 1-minute timing accuracy, supporting 24-hour/7-day weekly programming for flexible scheduling.
✅ Multiple Operation Modes
- ON: Manual permanent ON
- OFF: Manual permanent OFF
- AUTO: Automatic program execution
- Manual/Auto Toggle: One-key manual override for instant control
✅ User-Friendly Interface
Large LCD display for clear time and status viewing, with simple button operation for easy programming.
✅ Memory Retention
Built-in backup battery retains programmed settings during power outages, eliminating the need for reconfiguration after power restoration.
✅ Wide Compatibility
Suitable for 220V AC power systems, compatible with most household and commercial electrical loads.
✅ Compact & Durable Design
DIN rail mountable for easy installation in distribution boxes, with flame-retardant ABS housing for long-term reliability.
✅ Energy Saving
Automatically turns equipment on/off as scheduled, reducing unnecessary power consumption and lowering energy costs.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | KG316T |
| Control Voltage | AC 220V (50/60Hz) |
| Timing Accuracy | ±1 minute/month |
| Programming Capacity | 16 sets of on/off programs (expandable) |
| Time Range | 1 minute to 168 hours (1 week) |
| Contact Capacity | 25A (resistive load) |
| Power Consumption | ≤1W |
| Working Temperature | -10℃ ~ +55℃ |
| Humidity Range | ≤95% RH (non-condensing) |
| Mounting Type | DIN Rail / Panel Mount |
| Housing Material | Flame-retardant ABS |
| Protection Class | IP20 |
Button & Interface Description
Control Panel
| Button | Function |
|---|---|
| CANCEL/RESUME | Cancel/restore settings, reset timer |
| HOUR | Adjust hour setting |
| MINUTE | Adjust minute setting |
| WEEK | Set weekly cycle (1-7 days) |
| AUTO/MANUAL | Toggle between automatic and manual mode |
| SET UP | Enter/confirm programming settings |
| CLOCK | Set current time |
| Status Indicators | ON/AUTO/OFF mode display, Output/Power LED indicators |
Terminal Block
| Terminal | Function |
|---|---|
| Input L/N | Connect to AC 220V power supply |
| Output L/N | Connect to controlled load (lights, appliances, etc.) |
Application Scenarios
- Automatic control of home lighting, garden lights, water heaters, and air conditioners
- Scheduled on/off for fish tank equipment, water pumps, and home appliances
🏢 Commercial Use
- Street lighting, advertising signs, and neon lights control
- Office building lighting, ventilation, and air conditioning systems
- Shop shutter doors and automatic door control
🏭 Industrial Use
- Production line equipment timing control
- Agricultural irrigation and greenhouse ventilation systems
- Public facilities (water pumps, billboards, traffic lights)
Installation & Operation Guide
Step 1: Installation
- Mount the time switch on a standard DIN rail in a distribution box.
- Connect the input terminals (L/N) to the AC 220V power supply.
- Connect the output terminals (L/N) to the controlled electrical load.
- Ensure all connections are secure and power is off during wiring.
Step 2: Time Setting
- Press the CLOCK button, then use HOUR/MINUTE/WEEK to set the current time and date.
- Release the CLOCK button to save the current time.
Step 3: Program Setting
- Press the SET UP button to enter programming mode.
- Use HOUR/MINUTE/WEEK to set the first ON time and weekly cycle.
- Press SET UP again to set the corresponding OFF time.
- Repeat to set up to 16 on/off programs.
- Press CLOCK to exit programming mode.
Step 4: Mode Selection
- Press AUTO/MANUAL to toggle between ON, AUTO, and OFF modes.
- Select AUTO for automatic program execution.
Package Contents
- 1 x KG316T Digital Time Switch
- 1 x User Manual
- 1 x Mounting Accessories (DIN rail clip)
Why Choose Our KG316T Time Switch?
🔹 High Precision: Microcomputer control ensures accurate timing for reliable operation.
🔹 Easy to Use: Simple button operation and clear display for hassle-free programming.
🔹 Energy Efficient: Automatically cuts power to idle equipment, reducing electricity bills.
🔹 Wide Application: Versatile design suitable for home, office, and industrial use.
🔹 Durable & Safe: Flame-retardant housing and built-in protection for long service life.
FAQ
Q: Will the programmed settings be lost during a power outage?
A: No, the built-in backup battery retains all settings during power outages, ensuring automatic operation resumes when power is restored.
Q: How many on/off programs can I set?
A: The KG316T supports up to 16 sets of independent on/off programs, meeting most daily scheduling needs.
Q: Is it suitable for outdoor use?
A: The time switch itself is IP20 rated for indoor use. For outdoor applications, install it in a waterproof distribution box.
Q: What is the maximum load it can control?
A: The standard model supports a 25A resistive load, suitable for most household and commercial equipment. For higher loads, use with a contactor.
Warranty & Support
Key Features
✅ Intelligent Microcomputer Control
Built-in high-precision clock chip with 1-minute timing accuracy, supporting 24-hour/7-day weekly programming for flexible scheduling.
✅ Multiple Operation Modes
- ON: Manual permanent ON
- OFF: Manual permanent OFF
- AUTO: Automatic program execution
- Manual/Auto Toggle: One-key manual override for instant control
✅ User-Friendly Interface
Large LCD display for clear time and status viewing, with simple button operation for easy programming.
✅ Memory Retention
Built-in backup battery retains programmed settings during power outages, eliminating the need for reconfiguration after power restoration.
✅ Wide Compatibility
Suitable for 220V AC power systems, compatible with most household and commercial electrical loads.
✅ Compact & Durable Design
DIN rail mountable for easy installation in distribution boxes, with flame-retardant ABS housing for long-term reliability.
✅ Energy Saving
Automatically turns equipment on/off as scheduled, reducing unnecessary power consumption and lowering energy costs.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | KG316T |
| Control Voltage | AC 220V (50/60Hz) |
| Timing Accuracy | ±1 minute/month |
| Programming Capacity | 16 sets of on/off programs (expandable) |
| Time Range | 1 minute to 168 hours (1 week) |
| Contact Capacity | 25A (resistive load) |
| Power Consumption | ≤1W |
| Working Temperature | -10℃ ~ +55℃ |
| Humidity Range | ≤95% RH (non-condensing) |
| Mounting Type | DIN Rail / Panel Mount |
| Housing Material | Flame-retardant ABS |
| Protection Class | IP20 |
Button & Interface Description
Control Panel
| Button | Function |
|---|---|
| CANCEL/RESUME | Cancel/restore settings, reset timer |
| HOUR | Adjust hour setting |
| MINUTE | Adjust minute setting |
| WEEK | Set weekly cycle (1-7 days) |
| AUTO/MANUAL | Toggle between automatic and manual mode |
| SET UP | Enter/confirm programming settings |
| CLOCK | Set current time |
| Status Indicators | ON/AUTO/OFF mode display, Output/Power LED indicators |
Terminal Block
| Terminal | Function |
|---|---|
| Input L/N | Connect to AC 220V power supply |
| Output L/N | Connect to controlled load (lights, appliances, etc.) |
Application Scenarios
- Automatic control of home lighting, garden lights, water heaters, and air conditioners
- Scheduled on/off for fish tank equipment, water pumps, and home appliances
🏢 Commercial Use
- Street lighting, advertising signs, and neon lights control
- Office building lighting, ventilation, and air conditioning systems
- Shop shutter doors and automatic door control
🏭 Industrial Use
- Production line equipment timing control
- Agricultural irrigation and greenhouse ventilation systems
- Public facilities (water pumps, billboards, traffic lights)
Installation & Operation Guide
Step 1: Installation
- Mount the time switch on a standard DIN rail in a distribution box.
- Connect the input terminals (L/N) to the AC 220V power supply.
- Connect the output terminals (L/N) to the controlled electrical load.
- Ensure all connections are secure and power is off during wiring.
Step 2: Time Setting
- Press the CLOCK button, then use HOUR/MINUTE/WEEK to set the current time and date.
- Release the CLOCK button to save the current time.
Step 3: Program Setting
- Press the SET UP button to enter programming mode.
- Use HOUR/MINUTE/WEEK to set the first ON time and weekly cycle.
- Press SET UP again to set the corresponding OFF time.
- Repeat to set up to 16 on/off programs.
- Press CLOCK to exit programming mode.
Step 4: Mode Selection
- Press AUTO/MANUAL to toggle between ON, AUTO, and OFF modes.
- Select AUTO for automatic program execution.
Package Contents
- 1 x KG316T Digital Time Switch
- 1 x User Manual
- 1 x Mounting Accessories (DIN rail clip)
Why Choose Our KG316T Time Switch?
🔹 High Precision: Microcomputer control ensures accurate timing for reliable operation.
🔹 Easy to Use: Simple button operation and clear display for hassle-free programming.
🔹 Energy Efficient: Automatically cuts power to idle equipment, reducing electricity bills.
🔹 Wide Application: Versatile design suitable for home, office, and industrial use.
🔹 Durable & Safe: Flame-retardant housing and built-in protection for long service life.
FAQ
Q: Will the programmed settings be lost during a power outage?
A: No, the built-in backup battery retains all settings during power outages, ensuring automatic operation resumes when power is restored.
Q: How many on/off programs can I set?
A: The KG316T supports up to 16 sets of independent on/off programs, meeting most daily scheduling needs.
Q: Is it suitable for outdoor use?
A: The time switch itself is IP20 rated for indoor use. For outdoor applications, install it in a waterproof distribution box.
Q: What is the maximum load it can control?
A: The standard model supports a 25A resistive load, suitable for most household and commercial equipment. For higher loads, use with a contactor.