LMM3Z Double Break MCCB High Breaking

Rated Operational Voltage:AC: 400V, 415V, 690V
Rated Insulation Voltage:1000V
Rated Impulse Withstand Voltage:12kV
Frame Size Current:100A,160A, 250A, 400A, 630A, 800A, 1000A, 1250A, 1600A
Rated Current:16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, 160A, 200A, 250A, 315A, 400A, 500A, 630A, 800A, 1000A, 1250A, 1600A
Number of Poles:3P, 4P
Rated Frequency:50Hz, 60Hz
Rated Ultimate Short-Circuit Breaking Capacity:35kA, 50kA, 65kA, 75kA, 85kA, 100kA, 120kA, 150kA
Rated Service Short-Circuit Breaking Capacity:100% of Icu
Total Breaking Time:≤15ms; Contact separation ≤3ms
Applicable Standards:IEC 60947-2
Certifications:CE, CB, CSA, TUV, CCC

LMM3Z MCCB High Breaking Manual

The LMM3Z series plastic case circuit breaker is a new product designed and developed by our company using international advanced technology and has obtained multiple patents. It has the characteristics of small compactness, modularization, high breaking, double breaking points, zero flashover, green and environmental protection. It is suitable for power distribution networks with AC 50HZ, 60Hz, rated operating voltage 690V and below, and rated current 12.5A to 1600A. It is used to distribute electric energy and protect lines and power equipment from overload, short circuit, under-voltage and other faults. It can also be used for infrequent switching of circuits and infrequent starting of motors under normal circumstances.
The LMM3Z series circuit breakers are also equipped with an intelligent controller, which not only increases the selection range of the setting current, but also has a liquid crystal display, overload setting current, short-circuit delay current, short-circuit instantaneous current and tripping time that can be set, short-circuit instantaneous three-stage protection and under-voltage protection; equipped with RS485 communication interface, MODBUS-RTU protocol; DL645 protocol, users can choose according to their needs. Remote signaling: breaking/closing, tripping, alarm and fault status indication; remote control: breaking, closing, reset; telemetry: three-phase current and N-phase current, grounding current, tripping memory function, and functions such as querying tripping record parameters, which further improves the reliability and continuity of power supply. This circuit breaker also has an isolation function (can be used instead of a load switch).
This series of products complies with GB/T14048.2, GB/T 22710, and IEC60947-2 standards, and has passed 3C, CE, and TSE certifications.

Technical Data

Type LMM3Z-100 LMM3Z-160 LMM3Z-250
Number of poles 3P/4P 3P/4P 3P/4P
Shell frame current 100 160 250
Rated current TM/MA 12.5/16/20/25/32/

40/50/63/80/100

16/20/25/32/40/50/

63/80/100/125/160

100/160/180/

200/225/250

Electronic 100 160 250
Rated insulation voltage Ui(V) 1000 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8 8
Rated voltage Ue(V) AC 400/415/690 50/60Hz AC 400/415/500/690 50/60Hz AC 400/415/500/690 50/60Hz
Flying arc distance(mm) 0
Short circuit breaking capability level N L M H S N L M H S N L M H S
Rated limit short circuit breaking capacity Icu(kA) AC 400/415V 35 50 85 100 150 35 50 85 100 150 35 50 85 100 150
AC 500V / 35 50 60 65 / 35 50 60 65 / 35 50 60 65
AC 690V / 6 8 10 / 6 8 10 / 6 8 10
Usage category A A A
Rated running short circuit breaking capacity Ics(kA) AC 400/415V 35 50 85 100 150 35 50 85 100 150 35 50 85 100 150
AC 500V / 35 50 60 65 / 35 50 60 65 / 35 50 60 65
AC 690V / 6 8 10 / 6 8 10 / 6 8 10
Rated short time resitant current Icw(kA)(1s) Type of stripper 3(micrologic 5.0A) 3(micrologic 5.0A) 3(micrologic 5.0A)
Remaining current protection Additional residual current protection module
Electrical life tese AC415V 10000 8000 8000
AC690V 1500 1500 1500
Mechanical life 20000 20000 20000

Type LMM3Z-400 LMM3Z-630 LMM3Z-1250/1600
Number of poles 3P/4P 3P/4P 3P/4P
Shell frame current 400 630 1250/1600
Rated current TM/MA 250/315/350/400 400/500/600 /
Electronic 400 630 630/800/1000/1250/1600
Rated insulation voltage Ui(V) 1000 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8 8
Rated voltage Ue(V) AC 400/415/500/690 50/60Hz AC 400/415/500/690 50/60Hz AC 400/415/500/690 50/60Hz
Flying arc distance(mm) 0
Short circuit breaking capability level L M H S L M H S M H
Rated limit short circuit breaking capacity Icu(kA) AC 400/415V 50 85 100 150 50 85 100 150 50 65
AC 500V 35 50 60 65 35 50 60 65 35 45
AC 690V 10 15 20 10 15 20 20 30
Rated running short circuit breaking capacity Ics(kA) AC 400/415V 50 85 100 150 50 85 100 150 50 65
AC 500V 35 50 60 65 35 50 60 65 35 45
AC 690V 10 15 20 10 15 20 20 30
Working with categories TM/MA micrologic 2/3 A A A
micrologic 5.0 B B B
Rated short time resitant current Icw(kA)(1s) 5(micrologic 5.0A) 5(micrologic 5.0A) 20(micrologic 5.0A)
Remaining current protection Additional residual current protection module
Electrical life tese AC415V 6000 5000 1500
AC690V 1000 1000 1000
Mechanical life 10000 10000 10000

 